Friedrich-Alexander-Universität Erlangen-Nürnberg

Integrated Telemedical System in Ophthalmology ITSO

Integrated Telemedical System in Ophthalmology ITSO

  • Telemedical System for Integrated Screening, Diagnosing and Therapy in Ophthalmology (PI Michelson, PI Hornegger, PI Schmauss) (in adjunction with Project A04 of Medical Valley Spitzencluster)
  • The rationale of ITSO is the integration of all ophthalmological medical process steps within one system.
  • All medical professionals – from the GP performing the telemedical retinal screening step to the eye doctor doing the Laser therapy- use the same webbased-electronic patient chart. Thus all data and images were easily accessible in this electronic chart. This increases the effectivity of medical Processes.


  1. 1.Comparison of Early Retinal Microvascular Changes and Microalbuminuria as Indicators for Increased Cardioascular Risk]. Huchzermeyer C, Schaller B, Schmid K, Schmieder RE, Michelson G. Klin Monbl Augenheilkd. 2011 Nov;228(11):1003-8.
  2. 2.New software analyses increase the reliability of measurements of retinal arterioles morphology by scanning laser Doppler flowmetry in humans. Harazny JM, Raff U, Welzenbach J, Ott C, Ritt M, Lehmann M, Michelson G, Schmieder RE. J Hypertens. 2011 Apr;29(4):777-82.
  3. 3.Combined Evaluation of Frequency Doubling Technology Perimetry and Scanning Laser Ophthalmoscopy for Glaucoma Detection Using Automated Classification. Horn FK, Lämmer R, Mardin CY, Jünemann AG, Michelson G, Lausen B, Adler W. J Glaucoma. 2010 Dec 16.
  4. Prevalence of glaucomatous optic nerve atrophy among a working population in Germany diagnosed by a telemedical approach]. Adler W, Wärntges S, Lausen B, Michelson G. Klin Monbl Augenheilkd. 2010 Nov;227(11):905-11
  5. Validation of Telemedical Fundus Images from Patients with Retinopathy. Michelson G, Laser M, Müller S, Weber F, Wärntges S. Klin Monbl Augenheilkd. 2010 Jun 17.
  6. Automated quality assessment of retinal fundus photos. Paulus J, Meier J, Bock R, Hornegger J, Michelson G. Int J Comput Assist Radiol Surg. 2010Nov;5(6):557-64.
  7. The papilla as screening parameter for early diagnosis of glaucoma. Michelson G, Wärntges S, Hornegger J, Lausen B Dtsch Arztebl Int. 2008Aug;105(34-35):583-9.


Mission

SAOT provides an interdisciplinary research and education program of excellence within a broad international network of distinguished experts to promote innovation and leadership in the areas

Optical Metrology
Optical Material Processing
Optics in Medicine
Optics in Communication and Information Technology
Optical Materials and Systems
and Computational Optics.